NT60 Fieldbus Stepper Driver

  •   NT60 is the RS485 Modbus high-performance driver which developed by Rtelligent. The driver is based on 32-bit DSP platform. NT60 integrates intelligent motion controlling fuction with build-in S-type motion profile. Acceleration and deceleration can be set separately. NT60 run Modbus/RTU protocol over RS485 network to control the driver and motor.
           Configurator Interface: USB to 485.
          
    Maximum Current: 5A.
          
    Power Voltage: 24-50V DC 36V or 48V recommended.
          
    Typical Application: Production line Li-on battery equipment Solar energy equipment 3Celectrical equipment.

  • tel:0755-29503086
  • Product Details

Description of driver functions


Functions Description of operations
Slave address setting SW1-SW5, the 5 DIP switches, are used to set the 32 slave addresses.Please select the appropriate setting according to the description of drive.
Baud rale setting

 

SW6-SW7, the two DIP switches, are used to select a total of 4 baud rates in total. The master and slave must be set to the same baud rate. Please selectthe corresponding position according to the drive panel.
Terminal matching resistor

SW8 is used to select the disable or enable for 120Ohm terminal registance."off " means disable. "on" means enable.

CN interface 4 single-ended input ports, 2 output ports, please see the table below for details.
Encoder interface

 

GND : Internal power supply output GND; +5 V : Internal power supply output 5V. When operating in the closed-loop mode, 5V power is supplied to the encoder. The maximum output current of this 5v signal should not exceed 150mA.IN2-, IN2+ : The differential input signal, the 5v level signal, can receive the pulse signal when the external pulse is open loop, and the quadrature encoder A phase signal in the closed loop mode. IN1-, IN1+ : Receives the quadrature encoder B-phase signal as the IN2 port.
Power and Motor interface V-, V+ is powered by DC power supply. 24 - 50V DC is recommended for the operating voltage range, the power supply is greater than 150W. A+, A-, B-, and B+ are respectively connected to the A and B phase windings of the two-phase motor. 
Indicator The drive has two indicators: the green one, a power indicator and twinkle upon the power up of drive; the red one, a fault indicator and twinkle in case of overvoltage and overcurrent. The red indicator goes off only when the fault is removed. The fault of drive can only be removed when the drive is powered on and enabled again.
RJ45 interface Network communication interface, also used to connect PC debugging software.


Installation dimensions of NT60 Fieldbus Stepper Driver 

Installation dimensions of NT60 Fieldbus Stepper Driver

Installation dimensions of NT60 Fieldbus Stepper Driver 


 


Slave address setting


Slave address setting
Slave address setting
 

The pin distribution of CN 

 

The pin distribution of CN

The pin distribution of CN 


 

 LED indication of NT60 Fieldbus Stepper Driver 

 LED indication of NT60 Fieldbus Stepper Driver

 LED indication of NT60 Fieldbus Stepper Driver 

 

advisory:NT60 Fieldbus Stepper Driver